MXR50020-DC 20kw dc dc converter power supply ev charging fast chargers module

MXR50020-DC is a high-performance 20kw DC input charging module with forced air cooling technology for stable temperature and efficient charging. It communicates using CAN and RS485, making it suitable for intelligent control systems. This module has over 97.5% peak efficiency, making it ideal for fast and reliable charging.
  •  

    The relationship between output power and input voltage is shown in Figure 1-1 (T≤55°C). When the input voltage is between 250Vdc and 850Vdc, the module can output maximum power.

     

     

    Figure 1-1 DC Input Power Limiting Curve

     

    When the charging module has rated input voltage, the allowed output power is 20kW. The relationship between output voltage and output current is shown in Figure 1-2

     

    Figure 1-2 Output voltage vs. Output current curve

     

    Temperature derating
    Below 55℃ ambient temperature, input voltage above 250Vdc, the module outputs 20kW at full power, and the maximum output current is 50A;
    At 55℃ ambient temperature, the module allows output power less than or equal to 20kW;
    At 75℃ ambient temperature, the module allows output power less than or equal to 10kW,
    Above 75℃ ambient temperature, the module output power drops to 0.

     

    Temperature Limiting Power Curve

     

    • Output Power
      20kw
    • Input Voltage
      150Vdc~850Vdc,DC+PE
    • Input Current
      <85A
    • Voltage Range
      0Vdc~500Vdc(Continuously Adjustable)
    • Current Range
      0~50A (Continuously Adjustable)
    • Voltage stabilized accuracy
      ≤±0.5%
    • Current stabilized accuracy
      ≤±1%
    • Current Sharing Imbalance
      ≤±1%
    • Ripple Peak to Peak
      ≤1%
    • Operating Temperatue
      -40℃~75℃, output derating above 55℃
    • Storage Temperature
      -40℃~80℃
    • Relative Humidity
      ≤95% RH
    • Altitude
      ≤ 5000m
    • MTBF
      >100000 hours
    • Size(W×D×H)
      240×350×87mm
    • Weight
      <9kg
    • Cooling Mode
      Forced air cooling
    • Communication Method
      CAN & RS485
    • Indicator
      Green: normal operation  Yellow: alarm   Red: fault LED digital tube
    • Certification
      ROHS
Inquiry