MXR100040-DC 40kw dc to dc power supply converter module for ev charging station
The dc to dc power supply converters 40 kW EV charging module is suitable for ev charging station and can provide charging for electric vehicles in a short period of time. It is designed for DC fast charging and is suitable for highway service areas and fast charging stations. It has safety features to protect it and the charging process. DC-DC charging modules are efficient at converting DC power into electricity for EVs, reducing energy waste and charging time.
-
EXCELLENT ADVANTAGES
>Ultra-high
Full-load operating temperature 50℃
MXR100040-DC can output full power at 50℃. effectively ensuring the charging speed in high temperature environment.
>Ultra-wide
Output constant power range 50v-1000v
MXR100040-DC's ultra-wide output voltage range and ultra-high output power are suitable for charging various electric vehicles and greatly improve the charging speed.POWER CHART
Function DetailsHot-pluggingHot-plugging charging modules, easy installation and maintenance.Current sharingAutomatical current sharing between modules, current imbalance less than 3%.Input over/under voltage protectionOutput overvoltage protectionOver temperature protectionShort circuit protectionInternal bus fault protection -
-
Output Power40kW
-
Input Voltage200Vdc~850Vdc, DC + PE
-
Input Current<110A
-
Voltage Range50-1000Vdc
-
Current Range0-133.3A continuously regulated
-
Rated Current40A
-
Voltage stabilized accuracy≤±0.5%(100V-1000V,0~20MHz)
-
Current stabilized accuracy≤±1%(Output current 20% rated current~100% rated current value)
-
Current Sharing Imbalance≤±3%
-
Ripple Peak to Peak≤1%
-
Operating Temperatue-40℃~75℃, output derating above 50℃
-
Storage Temperature-40℃~+75℃
-
Relative Humidity≤95% RH without condensation
-
AltitudeNo derating below 2000m,When the altitude is above 1000m, it needs to set the actual altitude value, the working temperature decreases by 1℃ for each additional 100 m
-
MTBF>500000 hours
-
Size(W×D×H)360×459×85mm
-
Weight≤20kg
-
Efficiency(full load)>97.5%
-
Cooling ModeFan cooling
-
Communication MethodCAN bus
-
Parallel Module Quantity≤60 pieces
-
IndicatorGreen: normal operation Yellow: alarm Red: fault
-
CertificationCE/TUV TUVus
-