MXR100200 is a low-voltage and high-current charging module, with three industry-leading advantages of ultra-wide constant power range, ultra-large output current, and ultra-high full-load operating temperature; at the same time, high reliability, high efficiency, high power factor, and high power density. , Low standby power consumption is also the main feature of this series of modules.
  •  

    Excellent advantages
    >Ultra-wide
    Output voltage range 40v-100v
    The ultra-wide output voltage range of MXR100200 can meet the charging requirements of low voltage.
    >Super charging current 200A
    The super charging current of MXR100200 can greatly reduce the charging time.

    Main features
    Wide output voltage range, 40-100VDC, suitable for low-speed EVs;

    Wide operating temperature range at full power,-40℃~50℃;

    Full load efficiency is higher than 95%, high efficiency in the whole working range, and more energy saving;

    Ultra-low standby power consumption, the whole series of produces are controlled within 8W;

    The current in the low-voltage area does not shrink, and the charging speed is faster;
    The module is built with residual pressure relief loop to reduce system cost and improve system reliability.

    Characteristic Curve

     

    • Output Power
      20kw
    • Input Voltage
      285-475Vac, three-phase + PE
    • Input Current
      <40A
    • Grid Frequency
      45-65Hz
    • Power Factor
      ≥0.99 @50%~100% full load output power
    • ITHD
      ≤5% @50%~100% full load output power
    • Output Voltage Range
      40-100Vdc
    • Output Current Range
      0~200A
    • Rated Current
      200A
    • Voltage stabilized accuracy
      ≤±0.5%
    • Current stabilized accuracy
      ≤±1% (output load 20%~100% rated range)
    • Current Sharing Imbalance
      ≤±5%
    • Ripple Peak to Peak
      ≤1%
    • Operating Temperatue
      -40℃~75℃, output derating above 50℃
    • Storage Temperature
      -40℃~+75℃
    • Relative Humidity
      ≤95% RH without condensation
    • Altitude
      ≤1000m without derating, >1000m, the working temperature decreases by 1℃ for each additional 100 m
    • MTBF
      >500000 hours
    • Size(W×D×H)
      226×395×84mm
    • Weight
      ≤11kg
    • Efficiency(full load)
      >95.5%
    • Cooling Mode
      Forced air cooling
    • Standby Power consumption
      8.5W+/-0.5W
    • Communication Method
      CAN bus
    • Parallel Module Quantity
      ≤60 pieces
    • Indicator
      Green: normal operation  Yellow: alarm   Red: fault